Buying: |
962 portable spectral photometer with 0°/45° geometry |
|||
|
||||
|
||||
ID | 1710 | |||
Categories | Measuring Devices | | |||
|
||||
Short description | 962 portable spectral photometer with 0°/45° geometry | |||
Price (in €) | on request | |||
|
||||
Manufacturer | ||||
Model | --- | |||
Year of manufacture | 0000 | |||
Warranty until | --- | |||
|
||||
Long description | 962 portable spectral photometers with 0 °/45 ° geometry Interchangeable screens (Optionally): 7 mm, 4 mm, 15 mm. between devices correspondence: 0.2 ΔEab. Short term repeatability: 0.10 ΔEab on white ceramics Normal observer: 2 ° and 10 °. 0 °/45 ° measuring geometry excellent device correspondence Project functions Tallness, clear LCDDisplay with graphics function Light, compact, portables device Variable measurement with and without aim device Opazität, colour strength and colour assortment Robust construction method Independently of net by accumulator company 962 is an inexpensive spectral photometer with 0 °/45 °–measuring geometry. It delivers fast and reliably exact colour information on various materials as for example colour, varnish, paper, plastic and textiles. Measuring functions and indexes 962 misses absolute values and difference values of the in the following performed colour metrical systems. The values can be given on each of nine light kinds for 2 ° and 10 ° normal observer: CIE XYZ, CIE Yxy, CIELAB, Hunter, CIELCH, CMC and white degree, yellow degree to E313 98 ASTM and Metamerie index to German Institute for Standardization 6172 Special project functions The X Rite spectral photometer 962 enables to the user to define different colour standards and to summarise to projects. Passport / Fail function 962 stores up to 1024 colour standards with passport / Fail Toleranzen. The passport / Fail assessment is indicated on the display as well as by red or green LED and an acoustic signal (with excess of the tolerance). Interchangeable measuring screens (optionally) With few handles the user can choose between different measuring screens with 4 mm, 7 mm and 15 mm of measuring opening. This function gives a quick, efficient adaptation possibility to the size of the measuring object to the operator. Opazität, colour strength and colour assortment 962 misses Opazität as well as three kinds of the colour strength, visually, chromatically or 3 area value. Also 555 colour assortments is possible with 962. This are the important identification numbers for the colour quality inspection by the processing of plastics, textiles and materials with varnished surfaces. Ergonomics friendly to operator In addition to the programmes integrated in the device which support the user with the measurement the device is also friendly to operator itself. 962 is compact, easy and with the wrist loop and the lateral shaped recessed grips comfortably to hold. The announcements are big and clear. The accumulator company guarantees flexibility by the application of the device. Device correspondence 962 has an overriding device correspondence – in particular according to other colour controlling systems. 962 offers an excellent correspondence to X Rites 964 as well as 968 0 °/45 spectral photometers. All devices communicate with X Rites quality assurance sound Rezeptiersoftware at Windows level. Optional accessories *Battery recharger unit *Exchange accumulator stack *Different change screens *Different application facilities and measuring accessories *UV filter *Software for the high class control *colour formulation software *Service and servicing contracts *Software trainings *Colour metrics trainings SPECIFICATIONS: MODELS 962 (7 mm) 962page (4 mm) 962 l (15 mm) CHANGE OPTICS (optionally) 4 mm of measurement (6.5 mm of target window) 7 mm of measurement (9.0 mm of target window) 15 mm of measurement (21.5 mm of target window) SOURCE OF LIGHT Gas filled wolfram lamp LIGHT KINDS A, C, D50, D65, D75, F2, F7, F11 and F12 NORMAL OBSERVER 2 ° and 10 ° RECEIVER Silicon photodiodes with more raised Blue delicacy SPECTRAL RANGE 400 nm 700 nm SPECTRAL INTERVALS 10 nm measurement 10 nm issue STORAGE CAPACITY 1024 standards with tolerance 2000 tests MEASURING AREA 0 200% of reflexion MEASURING TIME Little one 2 seconds DEVICE CORRESPONDENCE CIE L*a*b* 0.20 DE*ab average ones Divergence on 12 BCRA Tiles series II Maximum 0.40 DE*ab on one Tile SHORT TERM REPEATABILITY 0.10 DE*ab on white ceramics (Standard divergence) LIFE SPAN OF THE LAMP approx. 500,000 measurements ELECTRICITY SUPPLY Interchangeable accumulator stack (nickel Metallhydrid); 7.2 V 1.250 mAh NET PART 180 240 VAC, 50 60 hertz, 15 W max. LOADING TIME approx. 4 hours – 100% of capacity MEASUREMENTS PER LOAD 1,000 measurements within 8 hours OPERATING TEMPERATURE 10 ° C to 40 ° C maximum 85% of relative ones Air humidity (not condensing) SAFEKEEPING TEMPERATURE 20 ° C to 50 ° C WEIGHT 1.1 kg DIMENSIONS 10.9 cm (height; 8.4 cm (width; 19.6 cm (length) PROVIDED ACCESSORIES Kalibrierstandards, operating instructions on CD, net part, Transport pocket OPTIONAL ACCESSORIES Battery recharger unit Exchange accumulator stack |
|||
|
||||
Weight | 1 | |||
Dimensions (LxWxH) | --- | |||
|
||||
Location | Germany | |||
Region | NRW | |||
|
||||
|
||||
View this article on the vendor's web site. |